Troubleshooting
When something goes wrong, find your symptom below and follow the fix. Everything here is done in the Watchdog window. If your problem is not listed, see Getting help at the bottom.
#Watchdog could not start its engine
Watchdog is built on a program it installs for itself, called the engine. If it does not start, the app shows Watchdog could not start its engine, with What happened to expand for details.
- Choose Try again.
- If it fails again, choose Repair the engine. This reinstalls the engine. Your investigations, settings and downloaded models are not touched.
You can also repair from inside the app: Settings → Setup → Repair or reinstall the engine.
#The engine installation stops or fails
Setup, or a repair, shows The installation did not finish with the reason. The usual cause is the connection: a VPN, a firewall or a flaky network can block the downloads. Another is running out of disk space; setup needs about 7 GB free, and the engine's own update after an app update about 1 GB.
Choose Try again. Whatever was already downloaded is kept, and installation resumes where it stopped. Start over begins from scratch. Show details displays the installer's log, which is worth copying into an issue if the problem persists.
If setup finishes with Some optional pieces could not be downloaded, Watchdog still works. It fetches each missing piece the first time it is needed. To try again now, open Settings → Setup and choose Download missing models. The card stays on Settings → Setup, with Show details for the log, until you try again.
On a work network that inspects secure connections, a download can fail with a certificate message such as "self-signed certificate in certificate chain". Watchdog trusts the certificates your computer already trusts, so this usually means the network's certificate is not installed on the computer. Ask whoever manages the network to install it, or try another network.
If the message says the app cannot install the engine because the installer files are missing, download the app again from the releases page.
#Add documents is turned off, or "Watchdog is still setting up"
Right after Watchdog is installed or updated, it finishes downloading its document and search libraries and its local models in the background. Until that is done, adding documents is turned off and says "Watchdog is still setting up". Everything else works. The Finishing setup… bar at the bottom of the sidebar shows how far along it is; the full download is about 4.5 GB, so on a slow connection it can take a while.
- The bar is still moving. Wait for it to finish. You can keep working in the meantime.
- The bar says "Setup did not finish". The download stopped, usually because the connection dropped. Choose Retry. Whatever was already downloaded is kept. If it keeps failing, open Settings → Setup, choose Show details and look at the last lines of the log; the causes are the same as in The engine installation stops or fails.
- You quit Watchdog part-way. Nothing is lost. Setup continues by itself the next time Watchdog opens.
- Search shows only exact matches. Searching by meaning needs the search models, which arrive with the rest of setup. Results ranked by meaning return when it finishes.
#macOS or Windows will not open the app
On the first launch, your computer may say it cannot verify the developer of Watchdog. Follow the steps in the install guide: on a Mac, System Settings → Privacy & Security → Open Anyway; on Windows, More info → Run anyway.
#"Allow Watchdog to work in this investigation"
Watchdog only changes files in folders you have allowed. When you open an investigation in a folder that is not on the list, the app shows Allow Watchdog to work in this investigation instead of the investigation's screens. This happens after you move an investigation to a different folder outside the app, or remove access to the folder that holds it.
Choose Allow access… and confirm. If you would rather not, choose All investigations; nothing is changed.
#Watchdog needs permission to use a folder
When you choose a folder for investigations in setup or in New investigation, Watchdog asks permission to work in it. If you decline, it says it needs your permission and asks you to choose another folder or allow this one. A move or an export to a folder you have not allowed asks in the same way.
To see or change what is allowed, open Settings → Folder access. Allow a folder… adds one, and the trash button on a row removes it. Removing access deletes nothing; investigations inside that folder ask for access again the next time they are opened. See Folder access.
#Claude is not signed in
Document reading, Ask Claude and Web research each need a way to reach a model. If a run says no model sign-in is set up, or Ask Claude says Claude may not be signed in, open Settings → Models & keys and sign in again, or paste an API key. The sign-in opens in your browser and the app waits for you to finish; if the browser did not open, the app shows a link to the sign-in page. At the end of signing in, the browser is sent to an address beginning with localhost, which is a page on your own computer. If that page will not load, go back to Watchdog before trying again: the sign-in has often worked anyway, and the app says so within a few seconds. If it has not, a firewall, a VPN or a browser setting that blocks localhost is the likely cause.
The app waits 10 minutes for you to finish in the browser. If you are creating your Claude account or choosing a plan at the same time, that can take longer, and the app then says the sign-in timed out: press Sign in again, which is quick once the account exists. While the app is waiting, pressing Sign in again carries on with the same sign-in rather than starting a new one, so the browser tab you already have still works. If you closed that tab, press Cancel and sign in again.
Ask Claude and Web research always use Claude, even if the document-reading step is set to another provider, so they need a Claude sign-in or key either way. They can also be billed differently from document reading: Ask Claude and Research in Settings → Models & keys shows which they use. Set to Claude subscription, they need you signed in to Claude, and the sign-in button appears there when you are not. The app's sign-in check is approximate, so a question may still work; if one fails to start, this is the usual reason.
#A run or conversation set to use the subscription stopped because it would be billed
Watchdog checks that every call set to use your Claude subscription really does. A run stops, with every unfinished document still queued, and an Ask Claude or Web research conversation stops, when one of these happens:
- Claude Code is not signed in with your Claude account. Claude Code, the program Watchdog uses to reach Claude on a subscription, is signed in with an Anthropic Console account or a sign-in token, or found an API key on this computer, so its calls would be billed per token to that account. Open Settings → Models & keys and sign in again with your Claude account.
- A setting names another account. The message names a setting, such as
ANTHROPIC_API_KEYorANTHROPIC_AUTH_TOKEN, that sends Claude Code's calls past your sign-in. Remove it from this computer, or set Claude to use an API key instead. - Extra usage started paying. Your subscription's limit was reached and your Claude account is set to carry on with paid extra usage. Turn off extra usage in your Claude account's settings, or wait until the limit has reset before adding the documents again: while the limit is still passed, the next run stops again at its first paid call. If you want runs to carry on and pay for extra usage instead, turn on Allow extra usage under Settings → Claude subscription.
A run set to use the subscription keeps refusing Claude calls until it ends, and a stopped conversation refuses further questions: start a new one. If extra usage was the reason, Activity → Usage lists the calls that may have been charged, and the subscription stays off in that investigation until you choose I've checked this there.
A run or conversation on an API key stops the same way if Claude Code reports that it would bill something other than the key you chose. Watchdog ignores keys and settings in your computer's environment, so this is rare; the message says what Claude Code reported. If you meant to pay per token, switch Claude to an API key under Settings → Models & keys.
#The provider rejected the key, or the account is out of credit
If a run stops with "the provider refused the credentials or account", every document is still queued; nothing was set aside as failed. The model provider turned the request down: the API key is wrong, revoked, or lacks access to the model, or the account has run out of credit or quota. The message includes the provider's own explanation.
Check the key in Settings → Models & keys, or top up the account on the provider's site, then add the documents again. The run picks up what is still queued.
#"The key this investigation bills isn't on this computer"
The investigation was set, under Billing on its Overview, to bill a named key (for example "Work") that this computer does not have: it was deleted, or the folder came from a colleague whose keys have different names. Watchdog stops before sending anything rather than bill another account. Either add a key with exactly that name under Settings → Models & keys (Add a key, or Add key beside the provider), or choose another key, or Default, in the Billing card. See Billing.
#macOS asks whether Watchdog may use its "Safe Storage" in your Keychain
Watchdog encrypts your API keys with a key kept in your login Keychain, named "Watchdog Safe Storage". macOS lets the app that created that item read it without asking. It asks when a differently signed copy of the app tries: a test build, a copy built from source, or a release signed by a different developer. Choose Always Allow if you trust the copy you are running; choose Deny and Watchdog can't read your stored keys, so anything that needs one stops without sending anything. Updates to Watchdog's engine never cause this prompt; only the app itself reads the Keychain.
If you denied it by mistake, open Keychain Access, find "Watchdog Safe Storage", add Watchdog under Access Control, then restart Watchdog.
#"Watchdog couldn't read the key from this computer's secure storage"
The key was encrypted under another user account or on another computer, or the system's secure storage was reset (on Linux, the keyring may not be running or unlocked). Settings → Models & keys marks such keys "can't be read". Replace each one with the key itself, or delete it. On Linux, check that your keyring is unlocked, then restart Watchdog.
#A file could not be read
Watchdog could not convert the file to text, so it set it aside and carried on with the rest. The Documents screen lists it under Couldn't be read in the strip above the list, with the reason it failed. Common causes:
- Password-protected PDF — remove the password and try again.
- Corrupted file — try re-downloading or re-exporting it.
- Unsupported format — check the supported file types.
- "Timed out after 600s" — the file took more than 10 minutes to convert, usually a very long scanned PDF. Split it into smaller files and add them separately.
If you fixed the file yourself (removed the password, or downloaded or exported it again), choose Remove under Couldn't be read, then add the fixed copy with Add documents. Remove moves Watchdog's copy to your computer's trash, from where you can put it back until the trash is emptied; a file you chose with Add documents is still wherever you keep it. If the cause has passed without any change to the file, such as a download that failed, choose Try again: the files go back with those waiting to be added, and the Add documents dialog opens to read them.
#A recording failed or came out wrong
Recordings are transcribed on your computer during pre-processing. What goes wrong, and what to do:
- "The transcription model could not be downloaded." The first recording you add downloads the speech-recognition model (1.5 GB by default), and the connection failed. Check the connection, then add the file again, or download the model from Settings → Setup with Download now first.
- "This video has no sound track." The file has pictures but no audio, so there is nothing to transcribe. If it should have sound, export it again from wherever it came from.
- "This file could not be read as audio or video." The file is damaged, or is not the format its name says. Try opening it in another player; if that also fails, get a fresh copy.
- It takes a long time. Transcription runs on your computer and is the slowest step for a long recording: with the default model, an hour of audio took 20 to 35 minutes on a four-core test computer. Recordings are transcribed one at a time, and the run shows how far it has got ("Transcribing hearing.mp4, 12:05 of 1:02:05"). A smaller model in Settings is faster but makes more mistakes.
- The transcript is in the wrong language, or is nonsense. Language detection listens to the start of the recording, and music, silence or a greeting in another language can mislead it. Set Transcription language in Settings, then add the recording again.
- Names or figures are wrong. Speech recognition mishears uncommon names and numbers; this is the normal failure, not a fault. Click the timestamp beside the passage to hear it, and correct the fact in your own notes. A larger model makes fewer of these mistakes.
- The player says the format can't be played. The transcript is still there. Some formats (
.avi, and some.mkvfiles) cannot be played inside Watchdog; use Open original to play the recording in another app.
#A scanned document in another language reads badly
Watchdog reads a scanned page again in its own language when it can tell what that is (how). The document's Details tab says which language it is in and which pages were read in it, and why not, when they could not be:
- "Tesseract has no French language data on this computer." Install Tesseract's data for that language (with Homebrew on a Mac,
brew install tesseract-lang). Documents added after that are read in it. - The language was not detected. Its pages had too little text to tell. Before adding such a document, add a
language:line to its sidecar file. - A document partly in another language was added as first read. Choosing Read again in French (or the language named) at the confirmation step, before the document is sent, reads those pages in their language.
A document already added keeps the text it was first read with.
#A file was set aside
Two things set a file aside, and neither is an error. The Documents screen lists these under Set aside:
- It is an exact duplicate. Watchdog fingerprints every document by its content, so a file that is byte-identical to one already added, even under a different name, is set aside rather than processed twice. Nothing to do.
- No text was found. Watchdog found nothing readable in the file, even after OCR. Open the original and check it is legible; a very poor scan can produce no text at all. For a recording, it means no speech was heard: check that it plays with sound.
#A document failed during a run
A document whose extraction fails is logged and set aside, and the rest of the batch still completes. On the Documents screen, the strip above the list shows the failed documents with two buttons. Retry puts them back and runs them again. Requeue moves them back into the queue without running them. The Overview also shows failed documents with a Retry button, and Activity → Maintenance → Requeue failed documents does the same as Requeue.
The full output of any run, including the reason a document failed, is under Activity: select the run on the Jobs tab. Watchdog keeps the output of the last 50 runs, including after you close the app.
#The model declined to answer a document
A document can fail with "the model declined to answer this request". The provider's safety checks refused the page, and they refuse it again every time, so Watchdog stops after one try instead of paying for a second. This tends to happen with pages that are not really text, such as a scan whose text came out as rows of meaningless digits or symbols. Retrying the same document with the same model will fail the same way.
Open the original and check that it is readable. If it is not, remove the document or add a cleaner copy. If it reads fine, choose a different model for that step in Settings and use Retry on the failed document. See Models and cost.
#A long document has only one or two facts
A model sometimes stops early and keeps a single fact from a long report. Watchdog adds the document anyway and marks it Few facts; choose Retry all… at the top of the Documents screen, or open the document and choose Retry extraction. Either shows the cost before anything is sent. See Few facts and Retry extraction. If it keeps happening with the same document, save the model's reasoning for a retry and send it with your report.
#A document is marked Unreadable text
The text Watchdog took from some of its pages is codes or symbols rather than words, so the model had nothing to read there, and a retry would not help. Open the original: if those pages read normally, save or scan the file as an image and add that copy, so Watchdog reads it with OCR. See Text could not be read.
#Hitting rate limits
A rate limit is a cap on how much work the AI provider lets you do in a window of time. On a metered API key it is counted in tokens per minute, not documents, so a handful of large documents extracted at once can use it up even when the number of documents looks modest: one document can cost ten times the tokens of another. On a Claude subscription it is your plan's usage limit, which is shared with the rest of your Claude use.
Watchdog already holds new documents back on its own once it is close to your provider's real limit, discovered automatically from the provider's own responses. This works with the Claude API, OpenAI, DeepSeek, Gemini, local and OpenRouter routes, with nothing to configure. Claude subscription sign-in is the one exception: it never reports this number, so on that route the automatic backing-off does not engage, and lowering concurrency is the fix.
Two things help when a rate limit stops a run:
- Lower how many documents are read at once. In Add documents, open Options and lower Documents at once for that run. To change it for every run, set Extraction concurrency under Settings → Processing; see Processing for its defaults.
- Wait out the limit. In Options, switch on Wait out rate limits. Instead of stopping, the run sleeps until the limit resets and resumes by itself, repeating until the queue is done. This suits an overnight run.
Without it, the run stops cleanly on a rate limit. Nothing is lost: every document already processed is saved, so adding documents again picks up only what is still queued.
#A run stopped at the spending limit
The investigation has reached the spending limit set on its Overview. Nothing is lost: finished documents are kept and the rest stay queued. Raise the limit or choose Reset the count on the Spending limit card, then add documents again. See A spending limit for one investigation.
#A step routed to a local model fails immediately
A message that the local backend needs a base URL means the address of your model server has not been set. Open Settings → Models & keys, choose the local provider, and enter the server's address (for example http://localhost:11434/v1).
A connection error (refused, timed out) means the server at that address is not running, is not reachable from this computer, or the port is wrong. Check that your runner (Ollama, LM Studio, llama.cpp's server, vLLM and so on) is actually up and listening before trying again. Most local runners need no API key; if yours does, add one in Models & keys. See Local and self-hosted models.
#A run was interrupted after extraction
A run has two stages: reading each document with a model (the slow, paid part), then writing everything to the investigation in one pass and producing the briefing. If the second stage never got a chance to run — no briefing appeared, entity summaries look unfinished, or a message said nothing was written yet — the batch can be completed without re-reading anything.
The Overview shows A batch is waiting to be finished with a Finish button. Choose it, or add documents again, and the app finishes the batch. Activity → Maintenance → Post-processing runs only this wrap-up step. It is safe to run more than once: if it hits a rate limit part-way, nothing is written at all, and you run it again once the limit resets. Nothing in an unfinished batch is ever discarded.
#The computer went to sleep during a run
While a run is going, Watchdog asks the computer not to sleep, because a sleep partway through a call stops whatever was in flight. This uses the system's own facilities on a Mac and on Linux systems that have systemd. On other Linux systems and on Windows, there is no equivalent to fall back to, so a run there is not protected against sleep; keep the computer awake until it finishes. If a run is cut off, add the documents again and it resumes.
#Documents can't be added because a run is in progress
While documents are being added, Watchdog keeps a small lock file in the investigation so that a second run cannot start on the same files. There is nothing to release by hand: the lock clears itself.
- Documents are being added. A run on this computer is working. The Jobs tab in Activity shows it if the app started it. You can add more documents once it ends, or stop it there.
- A run stopped before it finished. If a run ends without finishing (the app or the computer shut down, or the run crashed), the next time the app looks at the investigation it sees that the run is gone, removes its lock at once and says so in one line on the Overview and in the strip above the Documents list. Documents the run had finished are kept. Add documents again to finish the rest.
- Being added on another computer. The investigation's folder is shared, for instance through a sync service, and a run on another computer holds it. Watchdog cannot see that computer's programs, so it goes by time instead: a run updates its lock every two minutes, and a lock that has not been updated for 15 minutes is treated as left behind and cleared. If the other computer was shut down mid-run, this computer can add documents about 15 minutes later. Don't run on two computers at once: a sync service can deliver one computer's changes after the other has written its own.
#A note was deleted or edited by mistake
Entity and document notes are rewritten from Watchdog's own records, so nothing is lost. Choose Activity → Maintenance → Rebuild notes. It rewrites every entity and document note, including the entity summaries, and calls no AI model. Your own Notes sections are kept as they are. A note you deleted comes back without its Notes section: open the note's History, select a version from before it was deleted, and choose Restore my notes. A page of your own (context.md, a briefing, a page Claude saved) can be put back the same way with Restore this version. See History and your notes.
#A dated fact is missing from the timeline, or shows only its year
The fact is still on its document and its entities; only its place on the timeline is missing. Watchdog places a date only when it can read it with confidence: the year must be printed, and a date written in figures that could be read two ways (03/04/2021) is placed at its year until a model settles which reading the document means. If that step could not run (a rate limit, the spending limit) or found no confident answer, the date stays as it was. In an investigation started before October 2026, a date the old reader could not read was erased; bringing the investigation up to date reads back the ones the fact's words still state. How it works explains the rules.
#Bringing an investigation up to date stopped partway
The steps that finished are kept; the rest are still listed under Activity → Maintenance → Bring this investigation up to date. A step that stops at the spending limit asks nothing further: raise the limit or reset the count, then run it again. A failed call (a rate limit, a provider outage) leaves its step waiting, and items it had already settled are not asked again. The Overview's banner, once hidden, does not come back for the same steps; Maintenance shows them until they are done. See Bringing an investigation up to date.
#A merge joined two different people or companies
Open Review → Merges, find the merge under Recent merges, and choose Undo merge. If the button is unavailable, the reason is shown beside it; see Merges.
#Updates fail
If the Update available button shows The update could not be downloaded. Try again in a moment, check your connection and choose it again. If Restart to update says Watchdog could not restart into the update, quit Watchdog completely and open it again to finish updating.
Check for Updates… (the Watchdog menu on a Mac, the Help menu on Windows and Linux) says "Watchdog could not check for updates" when it cannot reach GitHub. Try again later, and check for a VPN or firewall.
If updating keeps failing, download the newest installer from the releases page and install it over the old one; your investigations and settings are kept. An update that has installed but whose engine did not follow shows Updating the Watchdog engine on the next start. If that fails, use Try again or Repair the engine, as above.
#Skills look outdated after an update
The record skills — the document-type knowledge — update with the app. Each investigation also has its own copy of Claude's setup (the shortcut commands and instructions Claude uses in that investigation), and Watchdog brings that copy up to date by itself whenever a conversation starts or resumes. It cannot do so in a folder Watchdog hasn't been allowed to work in, and it does not happen if you open the investigation's folder in Claude Code outside the app. In either case, open Activity → Maintenance and choose Refresh Claude setup for the investigation.
The refresh rewrites the shortcut commands, Watchdog's part of Claude's instructions and Claude's settings. Anything you added to the instructions after Watchdog's part is kept, and so is a shortcut of your own saved under a name that does not start with watchdog-. Changes to Watchdog's own shortcuts and to Claude's settings file are replaced.
#An investigation moved or is missing
If you reorganized your files and Watchdog can no longer find an investigation, the Investigations list marks it and says what is wrong. Open its ⋯ menu and choose Move to another folder…, then pick the folder that now holds it, which points Watchdog at the new location. If the investigation's folder exists but Watchdog does not list it at all, choose Add existing folder… on the Investigations screen. Settings → Check vaults runs a health check on every investigation and lists any whose folder is missing or broken.
When you point Watchdog at a different folder, it asks permission to work there; see Folder access.
#Obsidian says "Vault not found"
You chose Open in Obsidian and Obsidian showed a "Vault not found" error. Obsidian only reads its list of vaults when it starts, so an investigation created while Obsidian was already running is invisible to it until you restart it.
Quit Obsidian completely (use Quit, not just close the window), then choose Open in Obsidian again.
#Getting help
The app keeps a log of what it does. Open Help → Show Log File to find it; it is worth attaching when you report a problem. The full output of any run is under Activity.
If something is not working, open an issue at github.com/tomcardoso/watchdog/issues (Help → Report an Issue opens the page). Include:
- What you did
- What you expected to happen
- What actually happened — copy and paste any error messages
- Your operating system and version, and the Watchdog version (shown at the bottom of the sidebar and under Settings → About)
- The log file, if you can share it. Check it first: it can contain file names and paths from your investigations.
- The diagnostics report, if the problem is in what Watchdog produced (see below). It is made to be posted publicly.
#Sending a copy of the investigation
Activity → Maintenance → Export a copy for troubleshooting offers two choices, in a folder you choose.
Diagnostics only (safe to share) writes one text file of counts and shapes. It is the one to attach to a public issue. It holds:
- how many documents there are of each file type and page count range, and how many facts, Review items, merges, possible duplicates and document requests
- how many records share a name, and how large those groups are
- which kinds of warning the processing log holds and how often, each reduced to its shape: file names and anything in quotes are removed and every number is written as N
- the models, calls, retries, tokens, cost and time of each run, and your operating system, Watchdog version and settings
It never holds a file name, document title, the name of a person or organization, an alias, a relationship, a fact, a quote, a figure, an identifier, a date or a summary. It is built from a fixed list of counts, so a record field added in a later version does not appear in it. No model is used. The dialog shows the whole report before it is saved. Read it before you post it: even counts can hint at things, such as the languages or kinds of documents you work with.
Full copy (private) writes one zip file of the investigation's records, for your own use: to keep beside the investigation, or to hand to a colleague you would show the documents to. Much of that is kept in hidden folders inside the investigation, which zipping the folder by hand can leave out. The zip holds:
- Watchdog's records of the documents and entities, including merges, your checks of facts and the processing history
- what the model extracted from each document
- the usage and cost records
- the briefings, and the entity and document notes
- a short note of the Watchdog version, your operating system and your settings
It never contains your API keys or sign-ins, your conversations with Claude, the app's log or earlier versions of files. The original documents, and the text read from them, are left out unless you turn on Include the original documents. They make a problem with reading a document possible to reproduce, but the file is much larger and more sensitive.
The dialog shows how large the copy will be before it is written. Even without the originals, the notes and extractions quote the documents and name the people and organizations in them, so treat the copy as investigation material.
When you report a problem, attach the diagnostics report to the issue. Never attach the full copy: issues are public.
#Sharing debugging information
Some problems, such as a model returning far fewer facts than it should, can only be explained by what the model wrote while thinking. Watchdog does not keep that unless you ask it to:
- Turn on Settings → Troubleshooting → Save model reasoning.
- Reproduce the problem: add the documents again, or use Retry extraction on the one that went wrong.
- Open Activity → Maintenance → Saved model reasoning, choose the run and choose Save a run's reasoning…. Watchdog writes one zip file to the folder you pick, with that run's reasoning, its usage record and its lines from the processing log. Nothing is uploaded.
- Send the zip to whoever is helping you, then turn the setting off again and choose Clear saved reasoning.
The reasoning can restate what your documents say, word for word. Treat the zip like the documents themselves: send it only to someone you would show them to, and never attach it to a public issue.
#Where next
Using Watchdog describes every screen. For settings such as concurrency and models, see Models, cost and settings.